Compare Maximum number of 4 items selected Super Start Extreme Standard Flooded Side Post Battery Group Size 78 800 CCA 115 Minute RC - 78EXT Part #: 78EXT Line: SSB Super Start Extreme Standard Flooded Side Post Battery Group Size 78 800 CCA 115 Minute RC 3 Year Limited Warranty Group Size (BCI): 78 Length (in): 10-3/4 Inch Width (in): 6-7/8 Inch Cold Cranking Amps (CCA): 800 CCA Cranking Amps (CA): 985 CA Reserve Capacity (min): 115 Minute Voltage (V): 12 Volt Battery Type: Standard Flooded Terminal Type: Side Post Positive Terminal Location: Side Left Height (in): 7-1/4 Inch Height (mm): 184mm Length (mm): 273mm Width (mm): 175mm Weight (Lbs): 41 Lbs. Flush Manifold Vent Cover: Yes Add Acid And Charge Required: No Show More Show Less
Compare Maximum number of 4 items selected Optima Red AGM Top Post, Side Post Battery Group Size 34/78 800 CCA 100 Minute RC - RED34/78 Part #: RED34/78 Line: OBT Optima Red AGM Top Post, Side Post Battery Group Size 34/78 800 CCA 100 Minute RC 3 Year Limited Warranty Group Size (BCI): 34/78 Length (in): 10-1/16 Inch Width (in): 6-15/16 Inch Cold Cranking Amps (CCA): 800 CCA Cranking Amps (CA): 1000 CA Reserve Capacity (min): 100 Minute Voltage (V): 12 Volt Battery Type: AGM Terminal Type: Top Post, Side Post Positive Terminal Location: Top Left, Side Left Height (in): 7-7/8 Inch Weight (Lbs): 38.8 Lbs. Amp Hour (Ah): 50 Ah Flush Manifold Vent Cover: Yes Show More Show Less
Compare Maximum number of 4 items selected Optima Red AGM Side Post Battery Group Size 78 800 CCA 100 Minute RC - RED78 Part #: RED78 Line: OBT Optima Red AGM Side Post Battery Group Size 78 800 CCA 100 Minute RC 3 Year Limited Warranty Group Size (BCI): 78 Length (in): 10-1/16 Inch Width (in): 7-5/16 Inch Cold Cranking Amps (CCA): 800 CCA Cranking Amps (CA): 1000 CA Reserve Capacity (min): 100 Minute Voltage (V): 12 Volt Battery Type: AGM Terminal Type: Side Post Positive Terminal Location: Side Left Height (in): 7-1/4 Inch Weight (Lbs): 39.54 Lbs. Amp Hour (Ah): 50 Ah Flush Manifold Vent Cover: Yes Show More Show Less
Compare Maximum number of 4 items selected ACDelco Standard Flooded Side Post Battery Group Size 78 800 CCA 110 Minute RC - 78G Part #: 78G Line: ACD ACDelco Standard Flooded Side Post Battery Group Size 78 800 CCA 110 Minute RC 30 MONTH LIMITED WARRANTY Group Size (BCI): 78 Length (in): 10-3/16 Inch Width (in): 6-7/8 Inch Cold Cranking Amps (CCA): 800 CCA Cranking Amps (CA): 960 CA Reserve Capacity (min): 110 Minute Voltage (V): 12 Volt Battery Type: Standard Flooded Terminal Type: Side Post Positive Terminal Location: Side Left Height (in): 7-3/16 Inch Height (mm): 183mm Length (mm): 260mm Width (mm): 174mm Weight (Lbs): 37.8 Lbs. Amp Hour (Ah): 61 Ah Show More Show Less